Product Description
Solution Description:
Standard Semi-airtight refrigeration compressor which is used in some chilly room, like vegetable /fruit /meat/sea foods cold place. The horse power is commence from 2hpto 50hp. And the cooling ability is different due to the fact of distinct horse power. The substantial level of our compressor is substantial cooling capability with limited time, low noise.,and good following sales provider. I think it is your best selection.
Technological requirements:
We are a company, we can personalize products for you in accordance to your requirements.If you do not know which design is suitable for you, you could deliver information to us.We have many expert engineers to make a personalized remedy for you.
| Open Type CZPT Medium And Substantial Temperature Air-Cooled Condensing Unit | |||||||||||
| Model of units | RX-BZ- | RX-BZ- | RX-BZ- | RX-BZ- | RX-BZ- | RX-BZ- | RX-BZ- | RX-BZ- | RX-BZ- | ||
| 003H | 004H | 005H | 006H | 007H | 571H | 012H | 015H | 571H | |||
| Compressor design | 2DES-3 | 2CES-four | 4FES-5 | 4FES-six | 4DES-7 | 4VES-ten | 4TES-twelve | 4PES-fifteen | 4NES-20 | ||
| Applicable Temperature(ºC) | -5 ºC ~ -15 ºC | ||||||||||
| Refrigerant | R404 | ||||||||||
| Condenser | Quantity of Fan(pcs) | 2 | 2 | two | four | four | four | four | 4 | four | |
| Power of Enthusiast (w) | two*one hundred ninety | two*190 | two*a hundred ninety | 4*one hundred thirty five | 4*one hundred ninety | 4*a hundred ninety | 4*a hundred ninety | 4*250 | 4*420 | ||
| Ref.Capability | Evaporating | Ref. | 8300 | 15710 | 11110 | 13960 | 16890 | 21300 | 25800 | 29400 | 35200 |
| of | Temperature | Capacity (w) | |||||||||
| condensing models | -5ºC | Power (w) | 3310 | 4070 | 4380 | 5540 | 6620 | 8571 | 9860 | 11170 | 13320 |
| Evaporating | Ref. | 5520 | 6870 | 7370 | 9210 | 11190 | 13730 | 6780 | 18830 | 22900 | |
| Temperature | Potential (w) | ||||||||||
| -15ºC | Electrical power (w) | 2780 | 3440 | 3760 | 4700 | 5690 | 6580 | 8130 | 9090 | 11000 | |
| Coupling | Tube coupling | twelve | 12 | 12 | 16 | sixteen | 16 | sixteen | sixteen | 22 | |
| Suction coupling | 22 | 22 | 22 | 28 | 28 | 28 | 35 | forty two | 42 | ||
| Overall | Lenght (A) mm | a thousand | 1000 | 1571 | 1170 | 1170 | 1170 | 1200 | 1340 | 1560 | |
| dimension | Width(B) mm | 820 | 820 | 820 | 900 | 900 | 900 | 900 | 900 | 900 | |
| Height (H) mm | 590 | 590 | 690 | 1571 | 1120 | 1120 | 1320 | 1320 | 1420 | ||
| Installation dimension(D*E)mm | 644*786 | 644*786 | 644*786 | 800*860 | 800*860 | 800*860 | 830*860 | 990*860 | 1170*860 | ||
| Open up Type CZPT Medium And minimal Temperature Air-Cooled Condensing Unit | |||||||||||
| Model of units | RX-BZ- | RX-BZ- | RX-BZ- | RX-BZ- | RX-BZ- | RX-BZ- | RX-BZ- | RX-BZ- | RX-BZ- | ||
| 003L | 004L | 005L | 007L | 009L | 012L | 014L | 018L | 571L | |||
| Compressor product | 4FES-3 | 4EES-four | 4DES-5 | 4VES-seven | 4TES-nine | 4PES-twelve | 4NES-fourteen | 4HES-18 | 4GE-23 | ||
| Applicable Temperature(ºC) | -20ºC ~ -35ºC | ||||||||||
| Refrigerant | R404A | ||||||||||
| Condenser | Quantity of Enthusiast(pcs) | 2 | two | two | two | 4 | 4 | 4 | 4 | 4 | |
| Power of Supporter (w) | two*a hundred thirty five | 2*a hundred ninety | two*190 | 2*one hundred ninety | four*one hundred thirty five | four*190 | 4*a hundred ninety | 4*one hundred ninety | 4*250 | ||
| Ref.Capability | Evaporating | Ref. | 4640 | 5890 | 7030 | 8240 | 15710 | 11320 | 13950 | 19880 | 23400 |
| of | Temperature | Potential (w) | |||||||||
| condensing models | -25ºC | Energy (w) | 3060 | 3840 | 4550 | 5080 | 6350 | 6880 | 8580 | 12000 | 14270 |
| Evaporating | Ref. | 3590 | 4540 | 5420 | 6140 | 7760 | 8410 | 10520 | 15320 | 15320 | |
| Temperature | Ability (w) | ||||||||||
| -30ºC | Power (w) | 2660 | 3320 | 3940 | 4260 | 5380 | 5740 | 7240 | 1 0571 | one 0571 | |
| Coupling | Tube coupling | twelve | twelve | 12 | 16 | sixteen | 16 | 16 | 16 | 22 | |
| Suction coupling | 22 | 28 | 28 | 28 | 35 | 35 | 35 | 42 | fifty four | ||
| Overall | Lenght (A) mm | 940 | 1000 | one thousand | 1571 | 1170 | 1170 | 1170 | 1200 | 1340 | |
| dimension | Width(B) mm | 820 | 820 | 820 | 820 | 900 | 900 | 900 | 900 | 900 | |
| Height (H) mm | 540 | 590 | 590 | 690 | 1571 | 1120 | 1120 | 1320 | 1420 | ||
| Installation dimension(D*E)mm | 590*786 | 644*786 | 644*786 | 644*786 | 800*860 | 800*860 | 800/860 | 830*860 | 950*860 | ||
Application:
Chilly Room
Exhibition
FAQ:
Q1. When can I get the price ?
A1: We generally supply the quotation within 1-2 perform times following obtaining your in depth inquiry.
Remember to supply thorough demands like the capability, freezing solution, merchandise measurement, inlet &outlet temperatures, refrigerant and other particular specifications if any.
Q2. What is the Trade Time period?
A2: We accept Ex-operate manufacturing facility , FOB ZheJiang .
Q3. How prolonged is the production time?
A3: 60days after receiving down payment or Letter of credit history.
Q4 .What is the Payment term?
A4: By 100% T/T just before shipment or By L/C at sight.
Q5. What are your conditions of packing?
A5: Packing: export worthy package suitable for container transportation.
Q6. Do you take a look at all your items before supply?
A6: Yes, we have one hundred% examination just before supply.
Q7: Where is your manufacturing unit positioned?
A7: Our factory is located in HangZhou, ZheJiang province.
Q8: What is your warranty?
A8: Guarantee: 12months after business running.
Q9: Can we do our OEM emblem?
A9: Yes, for the goods with drawing supplied by you, we of course utilize your brand
Business infomation:
HangZhou CZPT Refrigeration Tools Co., Ltd. is a joint-inventory private enterprise positioned in HangZhou Industrial Park of Xingdong Region, HangZhou Metropolis, ZheJiang Province. Our manufacturing unit is adjacent to ZheJiang with hassle-free transportation. Welcome to visit the factory!
BX-freezing has passed ISO9001 good quality administration technique, EU CE certification and GC2 qualification for particular stress pipeline building. Our manufacturing facility has unbiased import and export proper. We are HangZhou Refrigeration Gear Engineering Engineering Heart and National Large-tech Enterprise. We are the university-organization cooperation foundation of HangZhou University, committed to talent cultivation and technological innovation. We have received about 50 invention and utility model patents in the subject of refrigeration gear.
We have a team of specialist and seasoned engineers engaged in the design and production of swift-freezing equipment for far more than ten years. We provide total solutions for foods processing generation lines. We concentrate on the style, development, production, revenue and upkeep of various sequence of rapid-freezing tools and foods deep-processing gear. Our merchandise are extensively used in foodstuff processing enterprises these kinds of as seafood, poultry, meat, baking, ice product, pasta, fruit and vegetable processing, and other processing meals.
BX-freezing quick freezing equipment strives to give specialist total gear solutions for domestic and foreign consumers. The principal goods are as follows:
1. Spiral freezer
two. Tunnel freezer
3. Fluidized freezer
four. Cold room
5. IQF line freezer
six. Refrigeration Device
seven. Other foodstuff processing tools
HangZhou CZPT Refrigeration Equipment Co., Ltd. is a fast developing professional company of fast-freezing products. The total items, major technology, affordable design, trustworthy top quality and excellent right after-sales service have been effectively received by many customers. There are previously More than 2,000 BX-freezing Collection models delivered worldwide. BX-freezing Group are devoted to supply you with skilled options, experienced merchandise.
|
US $2,000-100,000 / Set | |
1 Set (Min. Order) |
###
| Type: | Air-Cooled |
|---|---|
| Cooling Water: | Industrial Water |
| System Type: | Combined |
| Fans Species: | Frequency Fan |
| Noise Level: | Low |
| Application Fields: | Food Processing |
###
| Customization: |
Available
|
|---|
###
| Open Type Bitzer Medium And High Temperature Air-Cooled Condensing Unit | |||||||||||
| Model of units | RX-BZ- | RX-BZ- | RX-BZ- | RX-BZ- | RX-BZ- | RX-BZ- | RX-BZ- | RX-BZ- | RX-BZ- | ||
| 003H | 004H | 005H | 006H | 007H | 010H | 012H | 015H | 020H | |||
| Compressor model | 2DES-3 | 2CES-4 | 4FES-5 | 4FES-6 | 4DES-7 | 4VES-10 | 4TES-12 | 4PES-15 | 4NES-20 | ||
| Applicable Temperature(ºC) | -5 ºC ~ -15 ºC | ||||||||||
| Refrigerant | R404 | ||||||||||
| Condenser | Quantity of Fan(pcs) | 2 | 2 | 2 | 4 | 4 | 4 | 4 | 4 | 4 | |
| Power of Fan (w) | 2*190 | 2*190 | 2*190 | 4*135 | 4*190 | 4*190 | 4*190 | 4*250 | 4*420 | ||
| Ref.Capacity | Evaporating | Ref. | 8300 | 10250 | 11110 | 13960 | 16890 | 21300 | 25800 | 29400 | 35200 |
| of | Temperature | Capacity (w) | |||||||||
| condensing units | -5ºC | Power (w) | 3310 | 4070 | 4380 | 5540 | 6620 | 8010 | 9860 | 11170 | 13320 |
| Evaporating | Ref. | 5520 | 6870 | 7370 | 9210 | 11190 | 13730 | 6780 | 18830 | 22900 | |
| Temperature | Capacity (w) | ||||||||||
| -15ºC | Power (w) | 2780 | 3440 | 3760 | 4700 | 5690 | 6580 | 8130 | 9090 | 11000 | |
| Coupling | Tube coupling | 12 | 12 | 12 | 16 | 16 | 16 | 16 | 16 | 22 | |
| Suction coupling | 22 | 22 | 22 | 28 | 28 | 28 | 35 | 42 | 42 | ||
| Overall | Lenght (A) mm | 1000 | 1000 | 1010 | 1170 | 1170 | 1170 | 1200 | 1340 | 1560 | |
| dimension | Width(B) mm | 820 | 820 | 820 | 900 | 900 | 900 | 900 | 900 | 900 | |
| Height (H) mm | 590 | 590 | 690 | 1020 | 1120 | 1120 | 1320 | 1320 | 1420 | ||
| Installation dimension(D*E)mm | 644*786 | 644*786 | 644*786 | 800*860 | 800*860 | 800*860 | 830*860 | 990*860 | 1170*860 | ||
###
| Open Type Bitzer Medium And low Temperature Air-Cooled Condensing Unit | |||||||||||
| Model of units | RX-BZ- | RX-BZ- | RX-BZ- | RX-BZ- | RX-BZ- | RX-BZ- | RX-BZ- | RX-BZ- | RX-BZ- | ||
| 003L | 004L | 005L | 007L | 009L | 012L | 014L | 018L | 023L | |||
| Compressor model | 4FES-3 | 4EES-4 | 4DES-5 | 4VES-7 | 4TES-9 | 4PES-12 | 4NES-14 | 4HES-18 | 4GE-23 | ||
| Applicable Temperature(ºC) | -20ºC ~ -35ºC | ||||||||||
| Refrigerant | R404A | ||||||||||
| Condenser | Quantity of Fan(pcs) | 2 | 2 | 2 | 2 | 4 | 4 | 4 | 4 | 4 | |
| Power of Fan (w) | 2*135 | 2*190 | 2*190 | 2*190 | 4*135 | 4*190 | 4*190 | 4*190 | 4*250 | ||
| Ref.Capacity | Evaporating | Ref. | 4640 | 5890 | 7030 | 8240 | 10280 | 11320 | 13950 | 19880 | 23400 |
| of | Temperature | Capacity (w) | |||||||||
| condensing units | -25ºC | Power (w) | 3060 | 3840 | 4550 | 5080 | 6350 | 6880 | 8580 | 12000 | 14270 |
| Evaporating | Ref. | 3590 | 4540 | 5420 | 6140 | 7760 | 8410 | 10520 | 15320 | 15320 | |
| Temperature | Capacity (w) | ||||||||||
| -30ºC | Power (w) | 2660 | 3320 | 3940 | 4260 | 5380 | 5740 | 7240 | 10350 | 10350 | |
| Coupling | Tube coupling | 12 | 12 | 12 | 16 | 16 | 16 | 16 | 16 | 22 | |
| Suction coupling | 22 | 28 | 28 | 28 | 35 | 35 | 35 | 42 | 54 | ||
| Overall | Lenght (A) mm | 940 | 1000 | 1000 | 1010 | 1170 | 1170 | 1170 | 1200 | 1340 | |
| dimension | Width(B) mm | 820 | 820 | 820 | 820 | 900 | 900 | 900 | 900 | 900 | |
| Height (H) mm | 540 | 590 | 590 | 690 | 1020 | 1120 | 1120 | 1320 | 1420 | ||
| Installation dimension(D*E)mm | 590*786 | 644*786 | 644*786 | 644*786 | 800*860 | 800*860 | 800/860 | 830*860 | 950*860 | ||
|
US $2,000-100,000 / Set | |
1 Set (Min. Order) |
###
| Type: | Air-Cooled |
|---|---|
| Cooling Water: | Industrial Water |
| System Type: | Combined |
| Fans Species: | Frequency Fan |
| Noise Level: | Low |
| Application Fields: | Food Processing |
###
| Customization: |
Available
|
|---|
###
| Open Type Bitzer Medium And High Temperature Air-Cooled Condensing Unit | |||||||||||
| Model of units | RX-BZ- | RX-BZ- | RX-BZ- | RX-BZ- | RX-BZ- | RX-BZ- | RX-BZ- | RX-BZ- | RX-BZ- | ||
| 003H | 004H | 005H | 006H | 007H | 010H | 012H | 015H | 020H | |||
| Compressor model | 2DES-3 | 2CES-4 | 4FES-5 | 4FES-6 | 4DES-7 | 4VES-10 | 4TES-12 | 4PES-15 | 4NES-20 | ||
| Applicable Temperature(ºC) | -5 ºC ~ -15 ºC | ||||||||||
| Refrigerant | R404 | ||||||||||
| Condenser | Quantity of Fan(pcs) | 2 | 2 | 2 | 4 | 4 | 4 | 4 | 4 | 4 | |
| Power of Fan (w) | 2*190 | 2*190 | 2*190 | 4*135 | 4*190 | 4*190 | 4*190 | 4*250 | 4*420 | ||
| Ref.Capacity | Evaporating | Ref. | 8300 | 10250 | 11110 | 13960 | 16890 | 21300 | 25800 | 29400 | 35200 |
| of | Temperature | Capacity (w) | |||||||||
| condensing units | -5ºC | Power (w) | 3310 | 4070 | 4380 | 5540 | 6620 | 8010 | 9860 | 11170 | 13320 |
| Evaporating | Ref. | 5520 | 6870 | 7370 | 9210 | 11190 | 13730 | 6780 | 18830 | 22900 | |
| Temperature | Capacity (w) | ||||||||||
| -15ºC | Power (w) | 2780 | 3440 | 3760 | 4700 | 5690 | 6580 | 8130 | 9090 | 11000 | |
| Coupling | Tube coupling | 12 | 12 | 12 | 16 | 16 | 16 | 16 | 16 | 22 | |
| Suction coupling | 22 | 22 | 22 | 28 | 28 | 28 | 35 | 42 | 42 | ||
| Overall | Lenght (A) mm | 1000 | 1000 | 1010 | 1170 | 1170 | 1170 | 1200 | 1340 | 1560 | |
| dimension | Width(B) mm | 820 | 820 | 820 | 900 | 900 | 900 | 900 | 900 | 900 | |
| Height (H) mm | 590 | 590 | 690 | 1020 | 1120 | 1120 | 1320 | 1320 | 1420 | ||
| Installation dimension(D*E)mm | 644*786 | 644*786 | 644*786 | 800*860 | 800*860 | 800*860 | 830*860 | 990*860 | 1170*860 | ||
###
| Open Type Bitzer Medium And low Temperature Air-Cooled Condensing Unit | |||||||||||
| Model of units | RX-BZ- | RX-BZ- | RX-BZ- | RX-BZ- | RX-BZ- | RX-BZ- | RX-BZ- | RX-BZ- | RX-BZ- | ||
| 003L | 004L | 005L | 007L | 009L | 012L | 014L | 018L | 023L | |||
| Compressor model | 4FES-3 | 4EES-4 | 4DES-5 | 4VES-7 | 4TES-9 | 4PES-12 | 4NES-14 | 4HES-18 | 4GE-23 | ||
| Applicable Temperature(ºC) | -20ºC ~ -35ºC | ||||||||||
| Refrigerant | R404A | ||||||||||
| Condenser | Quantity of Fan(pcs) | 2 | 2 | 2 | 2 | 4 | 4 | 4 | 4 | 4 | |
| Power of Fan (w) | 2*135 | 2*190 | 2*190 | 2*190 | 4*135 | 4*190 | 4*190 | 4*190 | 4*250 | ||
| Ref.Capacity | Evaporating | Ref. | 4640 | 5890 | 7030 | 8240 | 10280 | 11320 | 13950 | 19880 | 23400 |
| of | Temperature | Capacity (w) | |||||||||
| condensing units | -25ºC | Power (w) | 3060 | 3840 | 4550 | 5080 | 6350 | 6880 | 8580 | 12000 | 14270 |
| Evaporating | Ref. | 3590 | 4540 | 5420 | 6140 | 7760 | 8410 | 10520 | 15320 | 15320 | |
| Temperature | Capacity (w) | ||||||||||
| -30ºC | Power (w) | 2660 | 3320 | 3940 | 4260 | 5380 | 5740 | 7240 | 10350 | 10350 | |
| Coupling | Tube coupling | 12 | 12 | 12 | 16 | 16 | 16 | 16 | 16 | 22 | |
| Suction coupling | 22 | 28 | 28 | 28 | 35 | 35 | 35 | 42 | 54 | ||
| Overall | Lenght (A) mm | 940 | 1000 | 1000 | 1010 | 1170 | 1170 | 1170 | 1200 | 1340 | |
| dimension | Width(B) mm | 820 | 820 | 820 | 820 | 900 | 900 | 900 | 900 | 900 | |
| Height (H) mm | 540 | 590 | 590 | 690 | 1020 | 1120 | 1120 | 1320 | 1420 | ||
| Installation dimension(D*E)mm | 590*786 | 644*786 | 644*786 | 644*786 | 800*860 | 800*860 | 800/860 | 830*860 | 950*860 | ||
Choosing the Right Air Compressor For Your Home
You will find that air compressors are indispensable tools for a variety of situations, including garages, home workshops, and basements. These tools can power a variety of tools, and each model is sized to suit the job at hand. Because air compressors have only one motor, they are lightweight, compact, and easy to handle. Using one air compressor to power several tools will also reduce the wear and tear on individual components. This article will introduce some important characteristics to look for when choosing the right air compressor for your home.
Positive displacement
A positive displacement compressor applies pressure to a fluid, whereas a centrifugal one does the opposite. A positive displacement compressor creates the desired pressure by trapping air and increasing its volume. Its discharge valve releases the high-pressure gas. These compressors are used in industrial applications and nuclear power plants. The difference between a positive and negative displacement compressor is that a positive displacement compressor can compress and release air at a consistent rate.
A positive displacement air compressor uses a reciprocating piston to compress air. This reduces the volume of the air in the compression chamber, and a discharge valve opens when the pressure reaches the desired level. These compressors are used in bicycle pumps and other pneumatic tools. Positive displacement air compressors have multiple inlet ports and have several configurations. Positive displacement air compressors have a single-acting and double-acting piston, and can be oil-lubricated or oil-free.
A positive displacement air compressor is different from a dynamic compressor. It draws air into the compression chambers and then releases the pressure when the valve is opened. Positive displacement compressors are common in industrial applications and are available in single-acting, double-acting, and oil-lubricated models. Large piston compressors have ventilated intermediate pieces and crossheads on gudgeon pins. Smaller models have permanently sealed crankcases with bearings.
Oil-free
Oil-free air compressors have some advantages over their oil-lubricated counterparts. They do not require lubrication oil because they are coated with Teflon. The material has one of the lowest coefficients of friction and is layered, so it slides past other layers with little effort. Because of this, oil-free compressors tend to be cheaper and still deliver comparable performance. Oil-free compressors are a good choice for industrial applications.
The life of an oil-free air compressor is significantly longer than an oil-lubricated counterpart. These models can operate up to 2,000 hours, four times longer than the average oil-lubed compressor. Oil-free compressors also have a significantly lower operating noise than their oil-lubricated counterparts. And because they don’t need oil changes, they are quieter. Some even last up to 2,000 hours.
An oil-free air compressor is a good choice if your application requires high levels of purity. Several applications require ultra-pure air, and even a drop of oil can cause product spoilage or damage to production equipment. In addition to the health risks, an oil-free air compressor reduces the costs associated with oil contamination and minimizes leaks. It also eliminates the need for oil collection, disposal, and treatment.
A typical oil-free air compressor is very efficient, requiring only about 18% of the full load horsepower. However, oil-free compressors have a higher risk of premature failure and are not recommended for large-scale industrial applications. They may also use up to 18% of the compressor’s full capacity. They may sound appealing, but you must make sure you understand the benefits of an oil-free air compressor before choosing one for your industrial applications.
Single-stage
A single-stage air compressor is designed to provide the power for a single pneumatic tool or device. These machines are generally smaller than two-stage compressors and produce less heat and energy. These machines aren’t designed for heavy-duty industries, but they are still highly effective for a variety of applications, including auto shops, gas stations, and various manufacturing plants. They can also be used in borewells, as they are suitable for small spaces with low air flow requirements.
A single-stage air compressor has one cylinder and two valves – the inlet and the delivery valves. Both of these valves function mechanically, with the inlet valve controlling torque and the delivery one controlling air pressure. Generally, single-stage compressors are powered by a gas engine, but there are also electric models available. The single-stage air compressor is the most common type of air compressor. It has a single cylinder, one piston, and one air cylinder.
The single-stage air compressors are used for small projects or personal use. A two-stage air compressor is more effective for industrial projects. Its longer air end life makes it more efficient. It is also more efficient for use in the automotive industry, where the engine has many cylinders. In general, single-stage compressors require a higher power level. The single-stage model is ideal for small projects, while a two-stage one is suitable for larger-scale arsenals.
CFM
The cubic foot-per-minute (CFM) of an air compressor is the output of the machine. In order to calculate the CFM level, start by looking at the compressor’s specifications. You should know how many cubic feet the unit can hold and how many pounds per square inch it can compress. Once you have these information, you can calculate the CFM. Now you can use these numbers to select an appropriate air compressor for your needs.
The most common way to increase the CFM of an air compressor is to turn the regulator down. By turning the dial down, the air compressor will produce more than 10 CFM. You can also try connecting two output valves. Make sure that the settings are adjusted properly before you begin. This will ensure that your air compressor is functioning at its maximum efficiency and lifespan. To increase the CFM of your air compressor, first check that your regulator is calibrated for the desired pressure level.
To calculate the CFM of an air compressor, first determine the tank volume of the machine. Then, multiply this volume by the time it takes to fill the tank. Then, divide the result by 60 seconds to calculate the CFM. Once you know how much air your machine can hold, you can choose a suitable air compressor. If you’re working in a confined area, you should buy a tool with a large tank.
PSI
The PSI of an air compressor is the pressure that it can output. A typical air compressor has a gauge connected to the airline at the bottom, next to it, or between the two. The gauge tells the actual pressure of the air compressor, while the cut-out pressure is determined by the manufacturer. The manufacturer recommends that you set the cut-out pressure twenty to forty PSI higher than the factory recommended pressure. If you want to set the pressure for your nail gun, you can use the cut-in and cut-out pressures on your compressor, and the tank won’t exceed this range.
The PSI of an air compressor measures the force that it can deliver, which is often in pounds per square inch. For most air tools, you need at least forty to 90 psi. In general, reciprocating air compressors work on an on/off basis. This relationship is known as the duty cycle. All air compressors are rated for a particular duty cycle, such as fifty percent on and twenty-five percent off.
The Psig of an air compressor is not free, as many people believe. The PSI of an air compressor is not free, but it is essential to maintain it for safe operations. If you’re having trouble maintaining a consistent pressure, consider turning down the PSI of your compressor by 2 psig. This will determine the critical pressure for the machine. You’ll also increase the amount of energy in the system by one percent.
Power source
The power source for an air compressor is crucial in its operation. Without the correct voltage and amperage, air compressors will not function properly. The power source must be close to the compressor so that it can plug into an electrical outlet. If it is too far from the outlet, the compressor may not be able to build enough pressure. When this happens, the fuse inside the air compressor will turn off to protect the user. The power source should be a safe distance from the compressor.
Most manufacturers do not specify the power source for an air compressor. Depending on the horsepower, the compressor will require approximately four amps of power. A one-horsepower compressor would draw about twelve amps. If it were powered by a typical 120-volt household supply, its motor would exceed the 15-amp breaker capacity. A larger air compressor, however, will require a separate 15-amp power source, making it impossible to use it with this type of power source.
The power source for an air compressor is typically electrical alternating current (AC) that is equivalent to the voltage on a standard wall outlet. A three-phase air compressor, on the other hand, requires a special AC supply with three electrical offset pulses. Regardless of the type of air compressor, the power source must be compatible with the incoming power service. One of the most common problems when attempting to connect an air compressor to an AC power source is undersized wire. This results in low voltage and high amperes, tripping of over-load relays and blown fuses.


editor by czh 2023-01-30

